9159金沙游戏场-9159金沙游戏艺场官网

  • 地址:济南市槐荫区鑫苑世家公馆2号楼2603室
  • 电话:0531-87568508 /
  • 手机:18653128690
  • 邮箱:jnyhrs@163.com
  • 微生物无菌室的装潢应该care哪些?
    来源: 浏览:次 发布日期:2020-06-08
    (1)无菌室应有内、外两间,内间是无菌室,外间是缓冲室。客厅容积不宜过大,以便于空气灭菌。内间面积2×2.5=5m2,外间面积1×2=2m2,高以2.5m以下为宜,都应有天花板。
    (1) There should be two rooms inside and outside the aseptic room. The inner room is the aseptic room and the outer room is the buffer room. The room volume should not be too large for air sterilization. The internal area is 2 × 2.5 = 5m2, the external area is 1 × 2 = 2M2, and the height is suitable for less than 2.5m, with ceiling.
    (2)内间应当设拉门,以减少空气的波动,门应设在离work台更远的地位上;外间的门更好也用拉门,要设在距内间更远的地位上。
    (2) Sliding doors shall be set in the inner room to reduce the air fluctuation. The doors shall be set at the farthest position from the workbench. The doors in the outer room shall also be set at the farthest position from the inner room.
    (3)在分隔内间与外间的墙壁或“隔扇”上,应开一个小窗,作接种过程中需要的内外传递物品的通道,以减少人员进出内间的次数,降低污染程度。小窗宽60cm、高40cm、厚30cm,内外都挂对拉的窗扇。
    (3) A small window shall be opened on the wall or "partition" separating the inside and outside of the room to serve as the necessary channel for internal and external transfer of goods during the vaccination process, so as to reduce the number of people entering and leaving the room and reduce the degree of pollution. The small windows are 60cm wide, 40cm high and 30cm thick, with opposite sashes hung inside and outside.
    (4)无菌室容积小而严密,使用一段时间下,房间内部温度很高,易于 应设置通气窗。通气窗应设在内室进门处的顶棚上(即离work台更远的地位),更好为双层结构,外层为百叶窗,内层可用抽板式窗扇。通气窗可在内室使用下、灭菌上开启,夜泖通空气。有条件可安装恒温恒湿机。
    无菌室装潢
    (4) The volume of aseptic room is small and tight. After using for a period of time, the indoor temperature is very high, so ventilation window should be set. The ventilation window shall be set on the ceiling at the entrance of the inner room (i.e. the farthest position from the workbench), preferably double-layer structure, the outer layer of which is louver, and the inner layer can be equipped with draw plate sash. The ventilation window can be opened after use in the inner chamber and before sterilization to circulate air. If possible, it can install constant temperature and humidity machine.
    care事项:
    matters needing attention:
    (1)无菌房间内部的work台,不论是什么材质、用途的,都要旨表面光滑和台面水平。
    (1) No matter what material and use, the working table in sterile room should have smooth surface and level table top.
    (2)在内室和外室各安装一个紫外灯(多为30W)。内室的紫外线灯应安装在经常work的座位正上方,离地上2m,外室的紫外线灯可安装在外室。
    (2) An ultraviolet lamp (mostly 30W) is installed in the inner and outer rooms respectively. The ultraviolet lamp in the inner chamber shall be installed directly above the frequently working seat, 2m from the ground, and the ultraviolet lamp in the outer chamber can be installed in the center of the outer chamber.
    (3)外室应有专用的work服、鞋、帽、口罩、盛有来苏儿水的瓷盆和毛巾、手持喷雾器和5百分比石炭酸溶液等。
    (3) the outer rooms should have special work clothes, shoes, caps, masks, pottery basins and towels containing the suer water, hand held sprayers and 5百分比 carbolic acid solutions.
    (4)内室应有酒精灯、常用接种工具、不锈钢制的刀、剪、镊子、70百分比的酒精棉球、工业酒精、载玻璃片、特种蜡笔、记录本、铅笔、标签纸、胶水、废物筐等。
    (4) The inner room shall be equipped with alcohol lamp, common inoculation tools, stainless steel knife, scissors, tweezers, 70百分比 alcohol cotton ball, industrial alcohol, glass plate, special crayon, record book, pencil, label paper, glue, waste basket, etc.
    感谢您的阅读,此文的文章来源:无菌室装潢更好优质的始末和小case请点击:吾们会继续努力的为您供给效劳,感谢您的支持!
    Thank you for your reading. For more information and questions about aseptic room decoration, please click: We will continue to work hard to provide you with services, thank you for your support!
    XML 地图 | Sitemap 地图