  • 对医疗净化工程有哪些误区?
    来源: 浏览:次 发布日期:2019-08-30
      1. 清洁和消毒的概念是错误的
      1. The concepts of cleanliness and disinfection are wrong.
      洁净室的鹄的是通过物理手段清除空气中的灰尘和细菌,而消毒是通过化学或物理手段消除或杀死环境或介质中的病原体和有害微生物。空气净化系统的建造不排除消毒的感化。
      The purpose of a clean room is to remove dust and bacteria from the air by physical means, while disinfection is to eliminate or kill pathogens and harmful microorganisms in the environment or media by chemical or physical means. The construction of air purification system does not exclude the role of disinfection.
      2. 净化影响舒适
      2. Purification affects comfort
      Now很多医院都建立了洁净手术室,存在着胸闷、气味重、噪音大、感觉不像上卫空调so舒适等小case。这些小case主要是由于医疗净化工程策划不合理遭成的。
      Nowadays, many hospitals have established clean operating rooms, which have many problems, such as chest tightness, heavy odor, high noise, and feeling less comfortable than traditional air conditioning. These problems are mainly caused by unreasonable design of medical purification engineering.
      3.在现代医疗建筑中使用上卫空调系统的错误
      3. Errors in Using Traditional Air Conditioning System in Modern Medical Buildings
      现代医院的中央空调系统本身就遭成了许多潜在的污染。对于医院的要紧职能部门,如外科、ICU、CCU等,应尽可能对空调系统进行净化,通过物理过滤降低风道内灰尘和细菌的房间内部风险。针对常见区域,推广了带高效过滤器的风机盘管系统。
      The central air-conditioning system of modern hospital itself has caused many potential pollution. For the important functional departments of the hospital, such as surgery, ICU, CCU, etc., the air conditioning system should be purified as far as possible, and the indoor risk of dust and bacteria in the air duct should be reduced by physical filtration. Aiming at common areas, the fan coil system with high efficiency filters is promoted.
      4、净化底与维护底的高误区
      4. High Misconceptions of Purification Cost and Maintenance Cost
    空气净化工程
      净化空调系统的总体底一贯只占20 - 30百分比的特殊客厅点缀和安装的正式动土总底(医疗设备除外),大约30百分比 - -50百分比的装潢底(主要是点缀水平对底有很大的影响),约20 - 30百分比的电气和高技术部件,大约10百分比 - -20百分比的医疗气体、给排水和消防部分。无法建立医疗净化室的一切费用,都归结为“净化”关键。
      The total cost of cleaning air conditioning system usually only accounts for 20 - 30百分比 of the total construction cost of special room decoration and installation (except medical equipment), about 30百分比 - 50百分比 of the decoration cost (mainly the decoration level has a great impact on the cost), about 20 - 30百分比 of the electrical and intelligent components, about 10百分比 - 20百分比 of the medical gas, water supply and drainage and fire protection parts. 。 All the expenses for the inability to establish a medical purification room can be attributed to the "purification" aspect.
      在医疗净化,只要净化空调系统策划科学、合理,正式动土质料是合格的,正确的使用和维护、净化室可以确保清洁,温度、湿度、压力和其他指标可以达到可控状态,制造一个安全、卫生的医疗环境,建造和维护底并不高。
      In medical purification, as long as the design of purification air-conditioning system is scientific and reasonable, the construction quality is qualified, the correct use and maintenance of purification room can ensure cleanliness, temperature, humidity, pressure and other indicators can reach a controllable state, creating a safe and sanitary medical environment, construction and maintenance costs are not high.