    无菌室也称接种室,是系统接种、纯化菌种等无菌操作的专用实验室。在微生物work中,菌种的接种移植是一项主要操作,这项操作的特点就是要保证菌种纯种,防止杂菌的污染。在一般环境的空气中,由于存在许多尘埃和杂菌,很易遭成污染,对接种work干扰很大。无菌室装潢为您介绍下微生物无菌室装潢策划规范化。
    The asepsis room, also known as the inoculation room, is a special laboratory for aseptic operations such as systematic inoculation and purification of bacteria. In the work of microbes, inoculation and transplantation of bacteria is a major operation. The characteristic of this operation is to ensure the pure species of bacteria and prevent the contamination of the bacteria. In the air of the general environment, because of the existence of many dust and miscellaneous bacteria, it is very easy to cause pollution and is very disturbing to the inoculation work. The decoration of the asepsis room is for you to introduce the standardization of the decoration design of the microorganism asepsis room.
    9159金沙游戏场
    无菌室应按照既经济又科学的原则来设置。其基本要旨有以下几点:
    The asepsis room should be set up according to the economic and scientific principles. The basic requirements are as follows:
    (1)无菌室应有内、外两间,内间是无菌室,外间是缓冲室。客厅容积不宜过大,以便于空气灭菌。内间面积2×2.5=5m2,外间面积1×2=2m2,高以2.5m以下为宜,都应有天花板。
    (1) asepsis room should be inside and outside the two, is within the asepsis room, is outside the buffer room. The volume of the room should not be too large to facilitate the sterilization of the air. Within the area of 2 x 2.5 = 5m2, outside the area of 1 x 2 = 2M2, high in 2.5m following the appropriate, should have the ceiling.
    (2)内间应当设拉门,以减少空气的波动,门应设在离work台远的地位上;外间的门好也用拉门,要设在距内间远的地位上。
    (2) shall be set up within the door, in order to reduce the fluctuation of the air, the door should be located in the most far away from the position of the worktable; the outer door is best to use sliding door, located in the far distance.
    (3)在分隔内间与外间的墙壁或“隔扇”上,应开一个小窗,作接种过程中需要的内外传递物品的通道,以减少人员进出内间的次数,降低污染程度。小窗宽60cm、高40cm、厚30cm,内外都挂对拉的窗扇。
    (3) in the inner and outer walls separated or sliding door, should open a window for the transfer of goods and the necessary channel inoculation process, to reduce the number of staff within, to reduce the pollution. The window width 60cm, height 40cm, thickness 30cm, both inside and outside of the window sash pull up.
    (4)无菌室容积小而严密,使用一段时间下,房间内部温度很高,易于 应设置通气窗。通气窗应设在内室进门处的顶棚上,好为双层结构,外层为百叶窗,内层可用抽板式窗扇。通气窗可在内室使用下、灭菌上开启,夜泖通空气。
    (4) the asepsis room volume is small and strict, after a period of time, the indoor temperature is very high, so the ventilation window should be set up. The ventilation window should be located on the ceiling of the entrance to the inner room. It is best to be a double layer structure, the outer layer is a shutter, and the inner layer can be used as a sash. The ventilated window can be opened after the use of the inner chamber and before sterilization to circulate the air.
    吾们会用优良的、贴切的效劳,让顾客感受到亲情般的温暖,始终视顾客的安全如己如亲。吾们会用自然优势打造产品的奇特之处,易于 给销费者带来享用产品时奇特的心境。